Cooper Menvier 1 Loop Addressable Panel

Availability:In Stock!

KSh 170,000.00

Cooper Menvier 1 Loop Addressable Panel
  • Available in 1, 2 and 4 loop versions
  • Up to 200 addresses per loop
  • Full network capability up to 126 panels
  • Event History Buffer (9,999 events) with Date/Time stamp
  • Soft addressing
  • Large versatile touch screen user interface
  • Multi-language selection capability
  • Integral battery and power supply
  • Flexible cause and effect programming
Order via Whatsapp

Description

Cooper Menvier 1 Loop Addressable Panel

With a capacity of 200 addresses and detailed cause-and-effect programing, it delivers a comprehensive user interface and logical menu structure. A network capability from 2 to 126 panels, makes the Cf3000 flexible for a diverse range of projects and is backed up by a large selection of devices and peripherals.

The Cooper CF3000 is a high-specification intelligent addressable control panel that is available in various loop configurations. These panels combine sophisticated functionality with simple operation and an aesthetically pleasing design.

The large capacity, ability to support complex cause and effect programming, and wide range of user-controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments.

The CF3000 uses soft addressing to minimize installation time and remove the potential for error associated with manual addressing. It can operate as a stand-alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local.

An extensive range of compatible intelligent addressable systems ancillaries are available to work with the CF3000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop.

 

Addresses per Loop 200
Number of conventional sounder circuits 4 monitored for open and short circuit
Auxiliary Fire Routing Equipment Output (Monitored) 24V 30 mA (max)
Auxiliary Fault Protection Equipment Output (Monitored) 24V 30 mA (max)
Auxiliary Fault Routing Equipment Output (Monitored) 12V 30 mA
System Operating Voltage 24V dc (nom)
Mains Input Supply 230V ac +1%/-15%
Class Change Facility Terminals for connection of external contacts, can also be instigated via input interface
Auxiliary Relay 1 set of changeover contacts operate in event of fire condition
Output Ports RS485, RS232 for connection of repeaters etc
Standby Duration Dependent on loop loading and battery configuration

Reviews

There are no reviews yet.

Be the first to review “Cooper Menvier 1 Loop Addressable Panel”

Your email address will not be published. Required fields are marked *