Ctec EP203 Automatic Extinguisher Panel

  • Certified to EN54-2/4 and EN12094-1 by the Loss Prevention Certification Board (LPCB)
  • Functions as a standard 3 zone fire panel with additional circuitry for controlling the release of fire-suppressing gas.
  • 128 x 64 pixel display.
  • Any combination of activated zones can be programmed to automatically start the panel’s extinguishant release sequence.
  • Manual release button and two keyswitches.
  • 3 conventional sounder circuits (two x 1st stage, one x 2nd stage).
  • Powerful 3A EN54-4 switch mode PSU.
  • Wide range of monitored inputs and auxiliary outputs.
  • Abort and hold inputs.
  • Time-stamped event log.
  • RS485 connections for up to 8 flush or surface remote status units with their own LCDs, manual release and mode switches. Single gang economy status units also available.
  • Wide range of engineering functions.
  • Optional relay expansion boards and single gang abort & hold buttons
  • Ideal for use in computer rooms, telecommunication centres, archive storage areas, museums, etc.
  • System line terminator included.

Out of stock

Compare

Description

Ctec EP203 Automatic Extinguisher Panel

LPCB certified to EN 12094-1 (the European standard for Fixed Firefighting Systems – Components for Gas Extinguishing Systems) and EN54-2/4, the EP203 three-zone automatic extinguisher panel epitomizes quality, durability, and reliability.

Specifically designed for use in areas housing expensive, dangerous or irreplaceable items of equipment, it features an intuitive 128 x 64-pixel display that gives clear and concise feedback to the user, installer, and commissioning engineer. It has six monitored inputs (including hold & abort), a time-stamped log, adjustable flood times, and volt-free changeover relays for fire, local fire, 1st stage active, 2nd stage active, extractor fan, and fault.

All of the panel’s electronics – apart from its powerful 3A EN54-4 switch mode PSU – are mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries is also available including remote status units, hold-off & abort buttons, line terminators, and relay boards.

Technical Specification

 

Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
Mains supply 230V 50/60Hz.
Mains rated current 810mA max.
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
EOL resistor value 6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Max. sounder output current 3 x 200mA.
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2KΩ normal; 1.8K-200Ω active; 150-0Ω short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%.

6 reviews for Ctec EP203 Automatic Extinguisher Panel

  1. https://Www.Waste-Ndc.pro/community/profile/tressa79906983/

    Woah! I’m really loving the template/theme of this website.
    It’s simple, yet effective. A lot of times it’s tough to get that “perfect balance” between superb usability and appearance.

    I must say that you’ve done a very good job with this.
    Additionally, the blog loads very quick for mme on Safari.
    Superb Blog! https://Www.Waste-Ndc.pro/community/profile/tressa79906983/

  2. Christoper

    I do not even understand how I finished up here, however I thought
    this submit used to be good. I do not know who
    you are but certainly you are going to a well-known blogger if you happen to are not already.

    Cheers!

    my web-site; nordvpn coupons inspiresensation (https://tinyurl.com/25nnj94c)

  3. Kristie

    This is my first time go to see at here and i am genuinely pleassant to read everthing at single place.

    My web-site: Eharmony special Coupon code 2025

  4. Frankie

    Thanks for sharing your thoughts about vpn.
    Regards

  5. Riley

    It’s amazing designed for me to have a web site, which what is a vpn meaning useful
    for my knowledge. thanks admin

  6. Arron

    I’ve been surfing online greater than three hours today, yet I never
    discovered any fascinating article like yours. It is lovely worth enough for me.
    In my opinion, if all web owners and bloggers made
    just right content material as you did, the internet shall be a lot more useful than ever before.

    Also visit my web site :: vpn

Add a review

Your email address will not be published. Required fields are marked *