C-TEC XFP 2 Loop 32 Zone Addressable Fire Alarm Panel

Availability:In Stock!

KSh 148,000.00

C-TEC XFP 2 Loop 32 Zone Addressable Fire Alarm Panel
  • Two programmable inputs.
  • Phased evacuation facility.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • 999 event monitoring.
Order via Whatsapp
Compare

Description

C-TEC XFP 2 Loop 32 Zone Addressable Fire Alarm Panel

C-TEC’s XFP two loop 32 zone addressable fire alarm panel offers high performance at a very competitive price.

LPCB certified to EN54 parts 2 & 4, it is supplied in durable metal enclosure, offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollo’s XP95/Discovery protocol.

Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels, it is one of Europe’s best-selling addressable fire panels.

Packed full of engineering features – please refer to the feature list below – the XFP502/X is also fully compatible with C-TEC’s Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.

Highlights

  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • An investigation delay period function.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network.
  • Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Technical Specification

Approvals/certifications Certified to EN54-2 & 4 by the LPCB.
Protocol/compatibility Apollo XP95/Discovery.
Mains supply 230V 50/60Hz.
Mains rated current 680mA maximum.
Internal power supply 27Vdc nominal.
Total output current limited to 3A @ 230Vac (Imax.A 270mA; Imin. 70mA).
Quiescent current 100mA (2 loops unloaded).
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
No. of loop drivers 2.
Max. loop output current 500mA (25V min; 34V max).
Max. loop length 1KM.
Max. addressable devices per loop 126.
No. of conventional sounder circuits 2 (Max. length per circuit is 500m).
EOL resistor value 6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Max. sounder output current 400mA.
Auxiliary relays 3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.
Other outputs 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.
Auxiliary inputs 2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).
PC connection PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.
Indicators 2 line x 40 character backlit display; 32 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; System Fault.
Connections Fixed, largest acceptable conductor size 1mm2.
Expansion connections 2-wire RS485 network/repeater connection available via optional AFP711 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or 500M (repeater network).
Product dimensions (mm) 410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid).
Construction & finish Metal.
IP Rating IP30.
Weight 4.5kg (without batteries).
Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%.