CTEC 2 ZONE CONVENTIONAL FIRE ALARM PANEL
Certified to EN54 parts 2, 4, and 13, C-TEC’s CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire, and fault relays, and combined keypad/key switch entry.
A wide range of engineering functions are also provided including selectable zone delays, coincidence, and non-latching zone facilities. Comprehensive test and fault-finding facilities are also provided.
Approvals/certifications | Certifed to EN54 Parts 2 & 4 by the LPCB., Certified to EN54-13 by Kiwa Telefication. |
---|---|
Mains supply | 230V 50/60Hz. |
Mains rated current | 350mA maximum. |
Internal power supply | 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault). |
Total output current limited to | 1.5A @ 230Vac (ImaxA eq 146mA). |
Quiescent current | 25mA (mains failed, internal sounder active, PSU & gen fault LED lit) |
Max battery size and type | 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah. |
No. of detector zone circuits | 2 (Max. length per circuit is 500m). |
Call point resistor value | 470 to 680Ω. |
Max. devices per detector zone | 25 detectors (or 32 detectors/manual call points combined). |
No. of conventional sounder circuits | 4 (Max. length per circuit is 500m). |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
Alarm voltage | 27V max, 20V min (final battery voltage) |
Max. sounder output current | 4 x 200mA (800mA total). |
Auxiliary relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
Open collector outputs | Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltag |
Other outputs | 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed). |
Auxiliary inputs | Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
Engineer (AL3) functions | Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters al |
Expansion connections | Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards. |
Product dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30. |
Weight | 1.75kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95%. |